    PH5500 Controller / Transmitter
    pH/ORP Controller/Transmitter
    PH5500 pH / ORP Controller / Transmitter
    Designed for precise pH / ORP control at complex industrial sites and unique housing design provides lower installation cost and easy operation. Symmetrical input, RS-485 output. PH5500 is your right wallmounting Controller / Transmitter with Large luminant LCD screen for easy reading.
    Wall mounting
    Designed for precise pH/ORP control at complex and harsh environment.
    High protection against electromagnetic interference.
    NEMA4X, IP65 rated: waterproof and anti-gas
    Multiple lines display of LCD screen, optional high luminance LED backlight
    Two relay circuits, users can select high-low control freely. Separately adjustable high and low
          set-point hysteresis(dead bands) prevent chattering of relays around the set points.
    Third relay Cleaning/Alarm function; users can set the cleaning frequency and time
    Scaleable isolated 0/4-20mA Outputs for pH/ORP
    Two optional electrode input: balanced input or asymmetric input
    Temperature value offset adjustment
    Glass electrode and antimony electrode are selectable to meet different industrial situations or
          HF(hydrofluoric acid) measurement situation
    Independent setting for process temperature(TST1) and calibration temperature(TST2) in manual
          temperature compensation (MTC) mode.
    RS-485 output
    Industrial process Boiler water Circulating water Pure water
    Industrial process Boiler water Circulating water Pure water
    pH Range -2.00-16.00 pH
      Resolution 0.01 pH
      Accuracy ±0.01 pH
      Signal Input Impedance ≥1012 Ω
    ORP Range -2000~2000 mV
      Resolution 1 mV
      Accuracy ±1 mV
    Temperature Temperature Range -10.0~110.0 °C
      Resolution 0.1 °C
      Precision ±0.3 °C
      Temperature Sensor Pt1000
      Temperature Compensation Automatic/Manual
    Signal Output/load Signal Output 4-20 mA (Adjustable)
      Current Accuracy 1%FS
      Load <500 Ω
    Data interface RS485 have
    Relay Ouput On/Off 2 SPST Relays
      Output 2.5A 230 VAC
      Cleaning/Alarm Relays 1X 2.5A
    Others Power 85~260 VAC or 24 VDC
      Working Temperature 0~60°C
      Humidity < 90%
      IP Rated IP65
      Installation Wall Mounting
      Dimensions (H×W×D) 160×188×108 mm
      Panel Cut Size 94.5×94.5 mm
      Weight 0.7 kg
         
    Model Specification images
    PH3000 pH/ORP Controller/Transmitter
    CS1540 pH sensor Versatile anti- poison Environmental waste water pH sensor
    CS1543 pH sensor Pure water, tap water, surface water and waste water
    CS1549 pH sensor High Temperature
    CS1668 pH combination sensor Sludge, Viscous Fluids Protein, hydrogen sulfide, Cold Low Ionic Water Silicates, Chromates, Cyanide, Sea water, Brine, Mining, Petrochemical, liquefied natural gas.
    CS1568 SNEX pH sensor Sludge, Viscous Fluids Protein, hydrogen sulfide, Cold Low Ionic Water Silicates, Chromates, Cyanide, Sea water, Brine, Mining, Petrochemical, liquefied natural gas.
    CS1768 pH combination sensor Designed for Harsh Industrial environment Sludge, Viscous Fluids Protein, hydrogen sulfide, Cold Low Ionic Water Silicates, Chromates, Cyanide, Sea water, Brine, Mining, Petrochemical, liquefied natural gas.
    CS1778 pH combination sensor Designed for flue gas desulfurization Traditional porous-liquid-junction pH sensors easy to be failured by reference electrode coating and contamination or fine particle clogging, poisoning. CS1778 SNEX pH sensor
    CS1788 pH combination sensor Designed for Ultra-pure Water/ Low ion concentration The red SNEX solid-state reference electrode system sustained releases potassium ion and chlorine ion, in addition to two sets of reference electrolyte permeability pores ensure stable and reliable readings.
    CS1628 resistant to HF pH sensor HF concentration<1000ppm
    CS1637 pH antimony sensor HF concentration>1000ppm
    CS1728 resistant to HF pH sensor HF concentration<1000ppm
    CS1737 pH antimony sensor HF concentration>1000ppm
    CS1733 pH sensor General purpose
    CS1753 pH sensor Process pH sensor with temperature compensation and connect to ground.
    CS2543 General purpose Platnium ORP sensor General Purpose
    CS2733 Platinum ORP sensor General Purpose
    CS2753 ORP sensor Designed for strong oxidative solution
    CS2628 SNEX ORP sensor Water quality monitoring, Sea water quality monitoring, Swimming pool, Waste water
    CS2668 SNEX ORP sensor Water quality monitoring, Sea water quality monitoring, Swimming pool, Waste water
    CS2768 SNEX ORP sensor Complex Industrial environment Anti-poison, long life span ORP sensor.
    Site Meter 亚洲全国最大的色惰网-一本大道香蕉大a√在线-亚洲三级片-综合图区欧洲偷自拍